Purpose
Indicates a logical start and creates an ON/OFF execution condition based on the ON/OFF status of the specified operand bit.
Ladder Symbol

  Variations

Applicable Program Areas


Operand Specifications
Description

LD is used for the first normally open bit from the bus bar or for the first normally open bit of a logic block. If there is no immediate refreshing specification, the specified bit in I/O memory is read. If there is an immediate refreshing specification, the status of the Basic Input Unit's input terminal is read and used.
LD is used in the following circumstances as an instruction for indicating a logical start.
   When directly connecting to the bus bar.
   When logic blocks are connected by AND LD or OR LD, i.e., at the beginning of a logic block.
The AND LOAD and OR LOAD instructions are used to connect in series or in parallel logic blocks beginning with LD or LD NOT.
At least one LOAD or LOAD NOT instruction is required for the execution condition when output-related instructions cannot be connected directly to the bus bar. If there is no LOAD or LOAD NOT instruction, a programming error will occur with the program check by the CX-Programmer.
When logic blocks are connected by AND LOAD or OR LOAD instructions, the total number of AND LOAD/OR LOAD instructions must match the total number of LOAD/LOAD NOT instructions minus 1. If they do not match, a programming error will occur. For details, refer to 3-2-7AND LOAD: AND LD and 3-2-8 OR LOAD OR LD.

 FLAGS 

There are no flags affected by this instruction.

Precautions


Differentiate up (@) or differentiate down (%) can be specified for LD. If differentiate up (@) is specified, the execution condition is turned ON for one cycle only after the status of the operand bit goes from OFF to ON. If differentiate down (%) is specified, the execution condition is turned ON for one cycle only after the status of the operand bit goes from ON to OFF.
Immediate refreshing (!) can be specified for LD. An immediate refresh instruction updates the status of the input bit for CPU Unit built-in inputs just before the instruction is executed.
For LD, it is possible to combine immediate refreshing and up or down differentiation (!@ or !%). If either of these is specified, the built-in input is refreshed from the CPU Unit just before the instruction is executed and the execution condition is turned ON for one cycle only after the status goes from OFF to ON, or from ON to OFF.

Example


contoh soal PLC beserta kunci jawaban


SOAL PG PLC BESERTA KUNCI JAWABAN

 





1.      Di dalam sistem kendali PLC fungsi utama dari PLC adalah  sebagai?a.Sebagai input yang memberikan masukan ke sistem kendalib.Sebagai jantung sistem kendali yang dapat mengidentifikasi masukan lalu di proses dandieksekusic.Sebagai input dan outputd.Sebagai input sajae.Sebagai output saja2.      Pada sistem kendali PLC terdapat peralatan input, yang termasuk kedalam peralatan inputpada sistem kendali PLC adalah?
 a.Tombol, sensor,saklarb.Mesin, lampuc. PLCd.Kontaktor magnete.Buzer 3.      Apa fungsi menu Download dalam software pemprograman PLC?
a.Memeriksa program yang telah dibuat apakah terdapat errorb.Untuk menghubungkan antara perangkat pemprograman dengan PLCc. Untuk memasukkan program ke dalam memori PLCd.Mengambil program yang terdapat di dalam memori PLCe.Untuk membuat Function seperti timer, counter, interlock, dll. 4.      Di dalam pengoperasian PLC memerlukan sumber catu daya, Sebutkan jenis catu daya yangada pada PLC?
a.Sambungan AC sajab.Sambungan DC sajac.Sambungan AC dan DCd.Sambungan paralele.Sambungan seri
 5.       Yang dimaksud dengan gambar di bawah ini adalah?
 
  a.Kontak Normally Openb. Kontak Normally Closec.Kontak Coild.Functione.Semua jawaban salah
 6. Yang dimaksud dengan gambar di bawah adalah?
 a.Catu dayab.Kontak Normally Closec.Kontak Coild.Input PLCe.Function
7.    Pada gambar rangkaian dibawah dapat kita gantikan dengan logic....

   
 
A.    AND
B.    NAND
C.   NOR
D.   OR
            E.     EXOR
8. Tiga bagian pokok dari PLC adalah ....
A.    Pemroses, memori dan input/ output
B.    Input, output dan  pemroses
C.   Memori, input dan output
D.   Memori, pemroses dan input
E.    Memori, pemroses dan output
9.    Fungsi counter pada fasilitas PLC berfungsi untuk ....
A.  menghitung naik
B.  mengukur waktu
C. mengakhiri program
D. menyimpan program
E.  menghitung turun
 10.     



Pada mnemonik diatas yang tepat untuk laddernya adalah....
A.     
   

   



    

     B.


   C.
 
   D.

   E.



11.   Sistem kontrol loop terbuka mempunyai karakteristik...
A.  Mempunyai umpan balik untuk mengkoreksi outputnya
B.  Tidak mempunyai peralatan output
C. Tidak mempunyai umpan balik untuk mengkoreksi outputnya
D. Tidak mempunyai peralatan input
E.  Tidak memiliki bagian proses .

    12.  Fungsi KEEP pada fasilitas PLC untuk ....
  1. menahan status suatu bit
  2. menghubungkan status bit
  3. menghitung bit
  4. mengukur input bit
  5. memindahkan bit
13.   Yang bukan termasuk peralatan input kendali PLC adalah....
  1. tombol
  2. saklar
  3. sensor
  4. photo electrik
  5.    lampu
1  14.  Untuk mentransfer program dari komputer ke PLC, menggunakan perintah ….

          A.  upload
  1. download
  2. save as
  3. edit
  4. save
15. Berikut ini instruksi-instruksi dasar pada diagram ladder, kecuali....
  1. download
  2. AND
  3. OR
  4. ANDNOT
  5. ORNOT